Irradiation chamber with 900W emitter.
The drawer is loaded with the products to be irradiated and pushed into the system, where it is automatically locked and the irradiation commenced.
The integral UV lamp is fitted with a shutter and only after the drawer is locked in position can radiation be emitted following the automatic opening of the shutter system.
Should the door be forcibly opened during irradiation, the UV emitter is automatically switched off.
There is an integral power-monitoring UV sensor and if the measured UV output falls below a set value, an alarm is generated.
The system has a small SPS with a display. The required irradiation time can be set and the time already expired is displayed.
There is also a permanently running operating hours clock and an operating hours clock which can be reset.
The irradiation procedure can be stopped if necessary by means of a push button.
Product Images
Drawer/Irradiation chamber with 450W emitters.
The drawer is loaded with the products to be irradiated and pushed into the system, where it is automatically locked and the irradiation commenced.
The integral UV lamp is fitted with a shutter and only after the drawer is locked in position can radiation be emitted following the automatic opening of the shutter system.
Should the door be forcibly opened during irradiation, the UV emitter is automatically switched off.
There is an integral power-monitoring UV sensor and if the measured UV output falls below a set value, an alarm is generated.
The system has a small SPS with a display. The required irradiation time can be set and the time already expired is displayed.
There is also a permanently running operating hours clock and an operating hours clock which can be reset.
The irradiation procedure can be stopped if necessary by means of a push button.
Product Images
Drawer/Irradiation chamber with 450W emitters.
The drawer is loaded with the products to be irradiated and pushed into the system, where it is automatically locked and the irradiation commenced.
The integral UV lamp is fitted with a shutter and only after the drawer is locked in position can radiation be emitted following the automatic opening of the shutter system.
Should the door be forcibly opened during irradiation, the UV emitter is automatically switched off.
There is an integral power-monitoring UV sensor and if the measured UV output falls below a set value, an alarm is generated.
The system has a small SPS with a display. The required irradiation time can be set and the time already expired is displayed.
There is also a permanently running operating hours clock and an operating hours clock which can be reset.
The irradiation procedure can be stopped if necessary by means of a push button.
Product Images
Small lightbox with a manually operated shutter.
The door of the box can be opened only when the shutter is closed preventing radiation from entering the chamber.
When the shutter is open, the door is locked.
No mains voltage supply is necessary for the lightbox.
Adaptor plates are available to fix different UV emitters, such as hand lamps or specific customer instruments.
Product Images
A UV-F 400, 450W large surface emitter in a large lightbox with a manually operated shutter.
The door of the box can be opened only when the shutter is closed preventing radiation from entering the chamber.
When the shutter is open, the door is locked.
No mains supply voltage is necessary for the lightbox and the UV emitter has a separate power supply.
Adaptor plates are available to fix different UV emitters, such as hand lamps, UV-F 400 or specific customer instruments.
Product Images
A UV-F 450, 450W large surface emitter in a large lightbox with a manually operated shutter.
The door of the box can be opened only when the shutter is closed preventing radiation from entering the chamber. When the shutter is open, the door is locked.
No mains supply voltage is necessary for the lightbox and the UV emitter has a separate power supply.
Adaptor plates are available to fix different UV emitters, such as hand lamps, UV-F 450 or specific customer instruments.
Product Images
10 / 11
Irradiation Chambers Overview
- Small surface UV emitter
- With shutter / aperture system
- Universal use
- 450W or 1000W UV-System
- Spacious chamber with door
- Slide-in bottom
- Timer control
- 450W or 1000W UV-System
- Spacious chamber with door
- Slide-in bottom
- Timer control
- 1000W UV-System
- Spacious chamber with door
- Integrated UV sensor
- 4 x 450W UV lamps
- Large-scale irradiation
- Stable drawer for heavy loads
- Filter plate frame
- 450W or 1000W UV lamps
- Drawer System
- Shutter System
- Universal use
- 450W UV lamps
- Drawer System
- Shutter system
- Customization
- 900W UV lamps
- Chamber with door lock
- Shutter system
- Cover control
- Small radiation chamber
- Manual Shuttersystem
- Automatic door locking
- For different UV lamps
- Small radiation chamber
- Manual Shuttersystem
- Automatic door locking
- UV-F 400 UV lamp
- Small radiation chamber
- Manual Shuttersystem
- Automatic door locking
- For UV-F 450 UV Emitters